...Power Amplifier IC Isolation Amplifiers 4kV peak Iso Amp 1 Features ±250-mV Input Voltage Range Optimized for Shunt Resistors Very Low Nonlinearity: 0.075% Maximum at 5 V Low Offset Error: 1.5 mV Maximum Low Noise: 3.1 mVRMS Typical Low High-Side Supply Current: 8mAMaximumat5V Input Bandwidth: 60 kHz Minimum Fixed Gain: 8 (0.5% accuracy) High Common Mode Rejection Ratio: 108 dB...
Active Member
|
![]() |
...Power Amplifier IC Isolation Amplifiers 4.25kV PEAK Iso Amp 1 Features ±250-mV Input Voltage Range Optimized for Shunt Resistors Very Low Nonlinearity: 0.075% max at 5 V Low Offset Error: 1.5 mV max Low Noise: 3.1 mVRMS typ Low High-Side Supply Current: 8 mA max at 5 V Input Bandwidth: 60 kHz min Fixed Gain: 8 (0.5% Accuracy) High Common-Mode Rejection Ratio: 108 dB...
Active Member
|
![]() |
DB-15-08B EI38 EI42 EI48 EI54 EI60 EI66 Power 230V AC encapsulated transformer Power Transformer: ※ EI 42 through hole transformer with thermal fuse ※ Operating temperature range: -10 ℃ to + 70 ℃ with full load ※ RoHS Compliance Product Electrical Specifications @ 25℃: Part Number Input Voltage Input Frequency Output Current Hi Pot Pri to Core Hi Pot Pri to Sec Hi Pot Sec to Core DB...
Verified Supplier
|
![]() |
...Power Packs 12V 900 AMP MINI Eergency Car Jump Starter Kit STARTER BOOST 20000MAH A13 Jump Starter Power Packs is a super useful gadget because not only can it start both 12V gasoline and diesel vehicles, but it charges your electronic devices too. 20000MAH A13 Jump Starter Power Packs SPECS: Capacity: 20,000mAh / 74WH Peak current: 900 Amps Starting current: 450 Amps...
Verified Supplier
|
![]() |
...Power Meter Technical specification Model # UC8751/UC851 Operation Mode Attenuation Setting mode Power Setting mode Range 0~45 dB +5 ~ -70dBm Resolution 0.01 dB 0.001 dB Repeatability ±0.02 dB (0 ~ 20 dB) ±0.05 dB (20~40 dB) ±0.02 dB Calibration Wavelength 1270 / 1310 / 1490 /1550 /1610 nm Fiber Type 9/125 um single mode SMF and MMF Connector Type FC/UPC Connector FC/SC/LC Option Insertion Loss ≤1.2 dB
Verified Supplier
|
![]() |
...Power Meter Model # UC8751 / UC8752 Operation Mode Attenuation Setting mode Power Setting mode Range 0~45 dB +5 ~ -70dBm Resolution 0.01 dB 0.001 dB Repeatability ±0.02 dB (0 ~ 20 dB) ±0.05 dB (20~40 dB) ±0.02 dB Calibration Wavelength 1270 / 1310 / 1490 /1550 /1610 nm Fiber Type 9/125 um single mode SMF and MMF adaptive Connector Type FC/UPC Connector FC/SC/LC Option Insertion Loss ≤1.2 dB...
Verified Supplier
|
![]() |
...Power 590KVA/472KW Over Speed Protection Generator set Model No. SC590E6A Standby power 650KVA/520KW Rated power 590KVA/472KW Output voltage 380V/3 phase Frequency 60 Hz Noise level(7m) 80 dB (silent type) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wire Start mode Electric Fuel consumption 101L/h (average) Rated currency(amps...
Verified Supplier
|
![]() |
...power generators Output Ratings: Gensets Model Prime Power Standby Power kW kVA kW kVA SP80E5 64 80 70 80 Voltage 380V-415V 220V-240V 190V-208V Amps 111-122 192-210 222-243 Engine Brand Perkins Engine Model 1104C-44TAG2 Alternator Brand Stamford Alternator Model UCI224G Control System DSE6020 / DSE7320 Standard Noise Level@7m (Soundproof Sets) 70 db...
Verified Supplier
|
Recommended Quality Verified Suppliers